

Base radiator E-VENT is built on the same principle as standard REGULUS-system products – water system made of copper, heat transfer system fins and aluminium covers. The only significant difference is that at the bottom of the aluminium fins package there is a recess of 100 mm in height and 60 mm in width. At the top of the recess, the fan connection components are installed.
The fan is clipped in (or out) of the recess without any tools – fast assembly with magnets. The fan increases the output of the heater by min, 30%. It is also possible to additionally influence the heating dynamics using a three-speed controller. The fan (or a set of fans depending on the length of the heater) connected to the BASE radiator is equipped with its own casing – a perforated cover, fastening elements in the heater’s recess (magnets) and a set of electric connections – cable, socket, plug.
E-VENT special features::
The fan installed at the bottom of the heater is intended to significantly increase its power and make heating more dynamic. The air movement caused by the heater with the fan ensures good distribution of the interior temperature and aids ventilation. The quiet running fan guarantees high comfort of use. The fan heater offers a wide range of options for controlling heat in the building – you can choose between one and three speed control variants.
The fan unit can be purchased together with the base heater, or its purchase can be postponed until the future, when the central heating system has a water heater adapted for this option. The only thing you need to remember is to provide electrical installation close to the heater base. Thanks to the fans, if such a need arises, it is possible to significantly increase the heater’s power without the necessity to increase its dimensions, , i.e. without the necessity to oversize it, e.g. for low parameters of the heating medium (condensation boilers, heat pumps) or to mount a smaller heater, but E-VENT in the absence of space for a heater of appropriate power for the heating needs.
Base radiator E-VENT
Height: 300-1115 mm
Lenght: 600, 1000, 1400, 1800 mm
Width: 90 mm
Connections:
side – GW 1/2 ” (Female thread)
bottom – GW 1/2 ” (Male thread, Spacing 50 mm)
Operating pressure: 1,5 MPa
Operating temperature: up to +110°С
Water capacity: 0,31-2,38 dm³
Weight: 2,9 – 23,2 kg
Distance between radiator and wall: 2 cm
FAN
Volume: max 26 dB(A)
Power: 6-12W
Voltage: 230V
Options:
Single-module fan – for the heater with the length 60 cm
Two-module fan – for the heater of the length.100 cm
Three-module fan – for the heater of length 140 cm
Four-module fan – for the heater of length 180 cm
Advantages of E-VENT radiator:
- copper-aluminium construction ensures high efficiency at low flow temperatures
- copper and aluminium are characterised by a high heat transfer coefficient (higher than steel and cast iron), heat is emitted even at a small temperature difference (heater and ambient)
- corrugated, very large heat exchange surface, an important feature for heating based on a low temperature of the heating agent – condensation boilers, heat pumps
- low own weight and small water capacity mean high heating dynamics, the heaters quickly reach their full rated power for a given flow temperature
- low thermal inertia enables energy-efficient and easily controllable heating
- Heating of the room takes place in a mixed way:
– by intense, wide-angle heat radiation from the front corrugated surface of the heater
– by convection
Air drawn in from below through the heater’s numerous convection chimneys flows through the heater’s interior, heats up after coming into contact with the surface of the pipes and fins and then flows out at the top through the perforated top casing. This double method of heat emission results in even heating of the air in the entire room.
Heat radiation does not heat the air but the object it falls on. The surface thus heated heats the air which washes over it – this phenomenon is called secondary convection.
E-VENT radiators may be used in any type of installation – copper, plastic or traditional steel. They cooperate with electric, gas, oil and solid fuel boilers. They can be connected to steam heating network. They work perfectly with condensing boilers and in systems operated by heat pumps. They can be filled with antifreeze (important for summer houses used periodically).
Any RAL colour included in the price
Colours from RAL K7 palette – powder varnish. Standard colour white – RAL 9003
Radiators in colours from the following colour chart (RAL K7) are available at list price, without an extra charge. An additional charge of 10% of the radiator’s list price shall apply to metallic colours, METALLIC version as well as convectors painted with structured paints.
The RAL K7 pattern book is available at our distributors.
NOTE: The colours displayed on the monitor may vary slightly from the actual RAL colours depending on the monitor’s parameters, therefore the presented list should be treated as indicative only! Please contact us by telephone to confirm colour matching.
Swimming pool version
SWIMMING POOL VERSION – these are special versions of wall mounted heaters intended for areas with increased humidity, such as swimming pools, car washes, laundries, conservatories, etc.
Their special resistance results from two features:
*construction – REGULUS®-system wall heaters are made of copper (exchanger) and aluminium (covers, lamellas), i.e. metals extremely resistant to corrosion. Unlike steel heaters, which quickly and easily succumb to destructive corrosion, copper and aluminium, when subjected to the process of oxidation, form oxides which, permanently connected to the non-oxidised material, constitute a tight protective layer for the process to continue deep into the structure of these metals.
*thickened layer of special varnish – an important protection, both against moisture and the impact of chemicals (used in swimming pools and other such facilities), is a durable, thickened layer of polyester-epoxy varnish hardened at high temperature. The mounting elements of the heaters are also made of aluminium profiles coated with facade powder varnish.
WARRANTY: 10 YEARS
POOL DESIGN PRICE = REGULAR PRICE OF THE HEATER – NO SURCHARGE – ATTENTION TEMPORARY PROMOTION
The radiators are symmetrical, their front and back are identical. They are reversible, i.e. they can be installed with an approach (connection) from the left or right side.
Technical data of the SOLLARIUS radiators for individual connection types
Type | Height [mm] | Lenght [mm] | Thickness [mm] | Power [W] 75/65/20 | Power [W] 55/45/20 | Power [W] 45/35/20 |
---|---|---|---|---|---|---|
E-VENT 3/60 without fan | 300 | 600 | 90 | 494 | 298 | 199 |
E-VENT 3/100 without fan | 300 | 1000 | 90 | 935 | 564 | 377 |
E-VENT 3/140 without fan | 300 | 1400 | 90 | 1432 | 863 | 578 |
E-VENT 3/180 without fan | 300 | 1800 | 90 | 1948 | 1174 | 786 |
E-VENT 4/60 without fan | 390 | 600 | 90 | 644 | 388 | 260 |
E-VENT 4/100 without fan | 390 | 1000 | 90 | 1185 | 714 | 478 |
E-VENT 4/140 without fan | 390 | 1400 | 90 | 1771 | 1068 | 715 |
E-VENT 4/180 without fan | 390 | 1800 | 90 | 2363 | 1424 | 954 |
E-VENT 5/60 without fan | 480 | 600 | 90 | 783 | 472 | 316 |
E-VENT 5/100 without fan | 480 | 1000 | 90 | 1477 | 890 | 596 |
E-VENT 5/140 without fan | 480 | 1400 | 90 | 2274 | 1371 | 918 |
E-VENT 5/180 without fan | 480 | 1800 | 90 | 3020 | 1820 | 1219 |
E-VENT 6/60 without fan | 570 | 600 | 90 | 922 | 556 | 372 |
E-VENT 6/100 without fan | 570 | 1000 | 90 | 1769 | 1066 | 714 |
E-VENT 6/140 without fan | 570 | 1400 | 90 | 2777 | 1674 | 1121 |
E-VENT 6/180 without fan | 570 | 1800 | 90 | 3676 | 2216 | 1483 |
E-VENT 8/60 without fan | 755 | 600 | 90 | 1224 | 738 | 494 |
E-VENT 8/100 without fan | 755 | 1000 | 90 | 2252 | 1357 | 909 |
E-VENT 8/140 without fan | 755 | 1400 | 90 | 3365 | 2028 | 1358 |
E-VENT 10/60 without fan | 935 | 600 | 90 | 1566 | 944 | 632 |
E-VENT 10/100 without fan | 935 | 1000 | 90 | 2954 | 1781 | 1192 |
E-VENT 10/140 without fan | 935 | 1400 | 90 | 4548 | 2741 | 1835 |
E-VENT 12/60 without fan | 1115 | 600 | 90 | 1844 | 1112 | 744 |
E-VENT 12/100 without fan | 1115 | 1000 | 90 | 3538 | 2133 | 1428 |
E-VENT 12/140 without fan | 1115 | 1400 | 90 | 5554 | 3348 | 2241 |
E-VENT 3/60 with a fan 230 V | 300 | 600 | 90 | 642 | 393 | 265 |
E-VENT 3/100 with a fan 230 V | 300 | 1000 | 90 | 1216 | 744 | 502 |
E-VENT 3/140 with a fan 230 V | 300 | 1400 | 90 | 1862 | 1139 | 769 |
E-VENT 3/180 with a fan 230 V | 300 | 1800 | 90 | 2532 | 1549 | 1046 |
E-VENT 4/60 with a fan 230 V | 390 | 600 | 90 | 837 | 512 | 346 |
E-VENT 4/100 with a fan 230 V | 390 | 1000 | 90 | 1541 | 943 | 637 |
E-VENT 4/140 with a fan 230 V | 390 | 1400 | 90 | 2302 | 1408 | 951 |
E-VENT 4/180 with a fan 230 V | 390 | 1800 | 90 | 3072 | 1879 | 1269 |
E-VENT 5/60 with a fan 230 V | 480 | 600 | 90 | 1018 | 623 | 421 |
E-VENT 5/100 with a fan 230 V | 480 | 1000 | 90 | 1920 | 1174 | 793 |
E-VENT 5/140 with a fan 230 V | 480 | 1400 | 90 | 2956 | 1808 | 1221 |
E-VENT 5/180 with a fan 230 V | 480 | 1800 | 90 | 3926 | 2401 | 1622 |
E-VENT 6/60 with a fan 230 V | 570 | 600 | 90 | 1199 | 733 | 495 |
E-VENT 6/100 with a fan 230 V | 570 | 1000 | 90 | 2300 | 1407 | 950 |
E-VENT 6/140 with a fan 230 V | 570 | 1400 | 90 | 3610 | 2208 | 1492 |
E-VENT 6/180 with a fan 230 V | 570 | 1800 | 90 | 4779 | 2923 | 1975 |
E-VENT 8/60 with a fan 230 V | 755 | 600 | 90 | 1591 | 973 | 657 |
E-VENT 8/100 with a fan 230 V | 755 | 1000 | 90 | 2928 | 1791 | 1210 |
E-VENT 8/140 with a fan 230 V | 755 | 1400 | 90 | 4375 | 2676 | 1808 |
E-VENT 10/60 with a fan 230 V | 935 | 600 | 90 | 2036 | 1245 | 841 |
E-VENT 10/100 with a fan 230 V | 935 | 1000 | 90 | 3840 | 2349 | 1587 |
E-VENT 10/140 with a fan 230 V | 935 | 1400 | 90 | 5912 | 3616 | 2443 |
E-VENT 12/60 with a fan 230 V | 1115 | 600 | 90 | 2397 | 1466 | 990 |
E-VENT 12/100 with a fan 230 V | 1115 | 1000 | 90 | 4599 | 2813 | 1900 |
E-VENT 12/140 with a fan 230 V | 1115 | 1400 | 90 | 7220 | 4416 | 2983 |
Room temperature | ||||||||
---|---|---|---|---|---|---|---|---|
tz | tp | 5 | 8 | 12 | 16 | 20 | 22 | 24 |
95 | 90 | 0.583 | 0.603 | 0.632 | 0.663 | 0.699 | 0.718 | 0.738 |
85 | 0.599 | 0.620 | 0.651 | 0.685 | 0.723 | 0.743 | 0.765 | |
80 | 0.617 | 0.639 | 0.672 | 0.708 | 0.748 | 0.770 | 0.794 | |
75 | 0.635 | 0.659 | 0.694 | 0.733 | 0.776 | 0.806 | 0.825 | |
70 | 0.655 | 0.681 | 0.718 | 0.759 | 0.806 | 0.832 | 0.859 | |
90 | 85 | 0.617 | 0.639 | 0.672 | 0.708 | 0.748 | 0.770 | 0.794 |
80 | 0.635 | 0.659 | 0.694 | 0.733 | 0.776 | 0.806 | 0.825 | |
75 | 0.655 | 0.681 | 0.718 | 0.759 | 0.806 | 0.832 | 0.859 | |
70 | 0.676 | 0.703 | 0.743 | 0.788 | 0.839 | 0.866 | 0.896 | |
65 | 0.699 | 0.728 | 0.770 | 0.819 | 0.874 | 0.904 | 0.937 | |
85 | 80 | 0.655 | 0.681 | 0.718 | 0.759 | 0.806 | 0.832 | 0.859 |
75 | 0.676 | 0.703 | 0.743 | 0.788 | 0.839 | 0.866 | 0.896 | |
70 | 0.699 | 0.728 | 0.770 | 0.819 | 0.874 | 0.904 | 0.937 | |
65 | 0.723 | 0.754 | 0.800 | 0.852 | 0.912 | 0.945 | 0.981 | |
60 | 0.748 | 0.782 | 0.832 | 0.889 | 0.954 | 0.990 | 1.030 | |
80 | 75 | 0.699 | 0.728 | 0.770 | 0.819 | 0.874 | 0.904 | 0.937 |
70 | 0.723 | 0.754 | 0.800 | 0.852 | 0.912 | 0.945 | 0.981 | |
65 | 0.748 | 0.782 | 0.832 | 0.889 | 0.954 | 0.990 | 1.030 | |
60 | 0.776 | 0.812 | 0.866 | 0.928 | 1.000 | 1.040 | 1.083 | |
55 | 0.806 | 0.845 | 0.904 | 0.972 | 1.050 | 1.095 | 1.143 | |
75 | 70 | 0.748 | 0.782 | 0.832 | 0.889 | 0.954 | 0.990 | 1.030 |
65 | 0.776 | 0.812 | 0.866 | 0.928 | 1.000 | 1.040 | 1.083 | |
60 | 0.806 | 0.845 | 0.904 | 0.972 | 1.050 | 1.095 | 1.143 | |
55 | 0.839 | 0.881 | 0.945 | 1.019 | 1.107 | 1.156 | 1.211 | |
50 | 0.874 | 0.920 | 0.990 | 1.072 | 1.169 | 1.225 | 1.286 | |
70 | 65 | 0.806 | 0.845 | 0.904 | 0.972 | 1.050 | 1.095 | 1.143 |
60 | 0.839 | 0.881 | 0.945 | 1.019 | 1.107 | 1.156 | 1.211 | |
55 | 0.874 | 0.920 | 0.990 | 1.072 | 1.169 | 1.225 | 1.286 | |
50 | 0.912 | 0.963 | 1.040 | 1.131 | 1.240 | 1.303 | 1.373 | |
45 | 0.954 | 1.009 | 1.095 | 1.197 | 1.320 | 1.391 | 1.471 | |
65 | 60 | 0.874 | 0.920 | 0.990 | 1.072 | 1.169 | 1.225 | 1.286 |
55 | 0.912 | 0.963 | 1.040 | 1.131 | 1.240 | 1.303 | 1.373 | |
50 | 0.954 | 1.009 | 1.095 | 1.197 | 1.320 | 1.391 | 1.471 | |
60 | 55 | 0.954 | 1.009 | 1.095 | 1.197 | 1.320 | 1.391 | 1.471 |
50 | 1.000 | 1.061 | 1.156 | 1.271 | 1.410 | 1.493 | 1.585 | |
45 | 1.050 | 1.119 | 1.225 | 1.354 | 1.515 | 1.611 | 1.719 | |
40 | 1.107 | 1.183 | 1.303 | 1.450 | 1.636 | 1.749 | 1.879 | |
55 | 50 | 1.050 | 1.119 | 1.225 | 1.354 | 1.515 | 1.611 | 1.719 |
45 | 1.107 | 1.183 | 1.303 | 1.450 | 1.635 | 1.749 | 1.879 | |
40 | 1.169 | 1.255 | 1.391 | 1.561 | 1.780 | 1.914 | 2.071 | |
35 | 1.240 | 1.337 | 1.493 | 1.691 | 1.951 | 2.115 | 2.308 | |
50 | 45 | 1.169 | 1.255 | 1.391 | 1.561 | 1.780 | 1.914 | 2.071 |
40 | 1.240 | 1.337 | 1.493 | 1.691 | 1.951 | 2.115 | 2.308 | |
35 | 1.320 | 1.430 | 1.611 | 1.844 | 2.160 | 2.363 | 2.609 | |
30 | 1.410 | 1.538 | 1.749 | 2.029 | 2.420 | 2.679 | 3.001 | |
45 | 40 | 1.320 | 1.43 | 1.611 | 1.844 | 2.160 | 2.363 | 2.609 |
35 | 1.410 | 1.538 | 1.749 | 2.029 | 2.420 | 2.679 | 3.001 | |
30 | 1.515 | 1.663 | 1.914 | 2.257 | 2.752 | 3.094 | 3.535 | |
40 | 35 | 1.515 | 1.663 | 1.914 | 2.257 | 2.752 | 3.094 | 3.535 |
30 | 1.636 | 1.811 | 2.115 | 2.542 | 3.194 | 3.666 | 4.307 |
Description:
tz – Flow temperature
tp – Return temperature
In the description of the heater parameters tz appears as the first value, tp as the second, and the room temperature as the third, e.g. 55/45/20
To calculate the heating power for non-standard supply parameters, divide the heating power for parameter 75/65/20 by the value read from the correction factor table.
For example, we are looking for the heating power for the S6/60 radiator for the parameter 70/50/20. The power for 75/65/20 is 922 W. In the table of correction factors, we read the coefficient for: tz = 70, tp = 50, room temperature = 20. In the table of correction coefficients read the value of the coefficient for: tz = 70, tp = 50, room temperature = 20. For these parameters the coefficient is: 1,246.
Therefore: 922/1,246 ≈740 W
HEATER ACCESSORIES SUPPLIED TOGETHER WITH THE RADIATOR, INCLUDED IN THE PRICE.
A set of wall hangers or a set of feet for floor mounting (one option to be selected), dowels, screws, air vent, in the bottom-supplied heaters a thermoregulatory valve with pre-adjustment, connection gaskets and installation manual.
Accessories and proposed control options for heaters with 230V fan
Fan module EV060/230V
for the heater with the length 60 cm
Fan module EV080/230V
for the heater of the length 80 cm
Fan module EV100/230V
for the heater of length 100 cm
Fan module EV120/230V
for the heater of length 120 cm
Fan module EV140/230V
for the heater with the length 140 cm
Fan module EV160/230V
for the heater of the length 160 cm
Fan module EV180/230V
for the heater of length 180 cm
Fan module EV200/230V
for the heater of length 200 cm
v.1.0
SALUS RT200 electronic temperature controller
LED lighting.
v.2.0
SALUS CONTROL
The electronic thermostat FC600 enables local control of both trench heaters and wall mounted radiators.
Features:
- Touch panel and picture menu
- automatic or manual fan speed regulation
- Possibility to connect supply temperature sensor CT10X
- time schedule: 5+2, 7-day, daily
- after expansion with internet gateway UGE600 remote control is possible
- memory for settings in case of power loss
- possibility of connecting wireless OS600 window/door opening sensor
- SmartPlug SPE600 can be connected
Use wiring between the duct fan and the thermostat (minimum 0.5 mm²)
v.3.0
SIEMENS CONTROL
Electronic thermostat that controls the operation of the fans.
Basic features:
- three-stage control of fan operation (automatic gear selection as a function of temperature, possibility of manual operation),
- automatic control of the thermal actuator,
- weekly work schedule programming function,
- flush mounted,
- installation in a standard 60mm electrical box
- compatible with remote control: IRA 211.
Wiring: between RDF 600T thermostat and control SP01 (SP06) electrical cable 6 x min. 0,5 mm2).
Electric cable 3 x min. between fan motor and control system. 0,5 mm2.
Thermoelectric actuator – T30NC 230V M30x1,5 – (currentless closed)
WARRANTY CONDITIONS
25 YEARS WARRANTY!!!
REGULUS®-system radiators are covered by a 25-year warranty – the warranty covers the tightness of heaters water system. Heater lifespan is comparable to the lifespan of copper installations and may be even several dozen years!
WARRANTY CONDITIONS
REGULUS®-system spółka jawna (general partnership) with its registered office at 51 Grażyńskiego Street in Bielsko-Biała, Poland, gives a warranty for its products: REGULUS®-system water-filled radiators.
The Manufacturer declares that the REGULUS®-system radiators are made in accordance with the EN-442 European Standard.
The Manufacturer’s warranty covers the leaktightness of the radiator water system. The warranty period varies depending on the place of application, thus, it is:
25 YEARS for radiators for facilities with microclimates typical of residential premises, offices and the like.
10 YEARS for radiators for facilities with high moisture of air and an increased hygiene and health regime, like swimming pools, car washes, drying rooms, vessels, commercial premises and all kinds of industrial buildings, including the port infrastructure.
- This warranty does not affect any of the consumer’s statutory rights relating to the product type’s incompatibility with the sales agreement.
- The User’s rights under this warranty may only be exercised via the company, from which the product was purchased. They may be exercised directly at the Manufacturer’s only if the point of sale, in which the product was purchased, has been closed down.
- This warranty shall be valid from the date of purchase as specified in the purchase document. The User’s rights under this warranty may only be exercised upon production of the purchase document along with the confirmed Warranty Card.
- If an event covered by the warranty occurs in the warranty period, the complaining User can demand the radiator to be replaced with another one of the same type.
- The new product shall be given to the User at the place of defect notification within 14 days from the date of notification. On reception of the new product, the User shall return the faulty radiator, unless the event has occurred during the ongoing heating season. In such a case, the faulty radiator shall be returned after the actual replacement.
- The Manufacturer shall cover the costs of the replacement of the faulty radiator with a new, fault-free one after receiving the relevant bill. The costs of this service shall be agreed on between the Manufacturer and the User in advance.
- Warranties for the control fittings shall be provided by their respective manufacturers.
- The Manufacturer’s warranty does not cover the functions and durability built in the thermostatic valves in bottom-fed radiators. These are covered by their manufacturer’s warranties.
ITEMS NOT COVERED BY THIS WARRANTY
- Any defects resulting from misuse of the product. Permissible system operating parameters: Water temperature – 110 °C, operating pressure – 1.5 MPa.
- Leakages resulting from incorrect installation of the radiator, the valve air vent or their components, and particularly from defrosting or using wrong sealing materials. Side-fed radiators are fitted with a rotatable half union for front sealing with gaskets.
- Defects and inconveniences resulting from incorrect installation or incorrect plumbing adjustment of the radiator and system water pollution.
- Mechanically damaged products (in particular with traces of impact, scratches, dents, twists – e.g. air vent or pipe sockets) shall not be subject to replacement.
- The warranty shall be void when the User or anyone else modifies or repairs any product of the REGULUS®-system company without authorization.
- The warranty shall be void when the mechanical filter mounted on the power supply of the central heating system, to which the REGULUS®-system radiators are connected, is removed. This particularly refers to a system with steel components.
- The REGULUS®-system company reserves the right to modify its products without prior notice.
ITEMS NOT AFFECTING THE WARRANTY
- Any kind of divisor mounted on the external surface of REGULUS®-system radiators, provided this does not damage the radiator water system.
- REGULUS®-system radiators mounted within open central heating systems.
- Radiators mounted within systems supplied directly by the municipal heat distribution network, not by way of a heat exchanger.
- Periodic emptying of the central heating system, provided the other system components allow for such an operation and the operation will not make the components corrode.
The User receiving the product together with the Warranty Card accepts all the above warranty terms.
- Types of connection
The radiators are symmetrical, their front and back are identical. They are reversible, i.e. they can be installed with an approach (connection) from the left or right side.
- Technical data
Technical data of the SOLLARIUS radiators for individual connection types
Type Height [mm] Lenght [mm] Thickness [mm] Power [W]
75/65/20Power [W]
55/45/20Power [W]
45/35/20E-VENT 3/60 without fan 300 600 90 494 298 199 E-VENT 3/100 without fan 300 1000 90 935 564 377 E-VENT 3/140 without fan 300 1400 90 1432 863 578 E-VENT 3/180 without fan 300 1800 90 1948 1174 786 E-VENT 4/60 without fan 390 600 90 644 388 260 E-VENT 4/100 without fan 390 1000 90 1185 714 478 E-VENT 4/140 without fan 390 1400 90 1771 1068 715 E-VENT 4/180 without fan 390 1800 90 2363 1424 954 E-VENT 5/60 without fan 480 600 90 783 472 316 E-VENT 5/100 without fan 480 1000 90 1477 890 596 E-VENT 5/140 without fan 480 1400 90 2274 1371 918 E-VENT 5/180 without fan 480 1800 90 3020 1820 1219 E-VENT 6/60 without fan 570 600 90 922 556 372 E-VENT 6/100 without fan 570 1000 90 1769 1066 714 E-VENT 6/140 without fan 570 1400 90 2777 1674 1121 E-VENT 6/180 without fan 570 1800 90 3676 2216 1483 E-VENT 8/60 without fan 755 600 90 1224 738 494 E-VENT 8/100 without fan 755 1000 90 2252 1357 909 E-VENT 8/140 without fan 755 1400 90 3365 2028 1358 E-VENT 10/60 without fan 935 600 90 1566 944 632 E-VENT 10/100 without fan 935 1000 90 2954 1781 1192 E-VENT 10/140 without fan 935 1400 90 4548 2741 1835 E-VENT 12/60 without fan 1115 600 90 1844 1112 744 E-VENT 12/100 without fan 1115 1000 90 3538 2133 1428 E-VENT 12/140 without fan 1115 1400 90 5554 3348 2241 E-VENT 3/60 with a fan 230 V 300 600 90 642 393 265 E-VENT 3/100 with a fan 230 V 300 1000 90 1216 744 502 E-VENT 3/140 with a fan 230 V 300 1400 90 1862 1139 769 E-VENT 3/180 with a fan 230 V 300 1800 90 2532 1549 1046 E-VENT 4/60 with a fan 230 V 390 600 90 837 512 346 E-VENT 4/100 with a fan 230 V 390 1000 90 1541 943 637 E-VENT 4/140 with a fan 230 V 390 1400 90 2302 1408 951 E-VENT 4/180 with a fan 230 V 390 1800 90 3072 1879 1269 E-VENT 5/60 with a fan 230 V 480 600 90 1018 623 421 E-VENT 5/100 with a fan 230 V 480 1000 90 1920 1174 793 E-VENT 5/140 with a fan 230 V 480 1400 90 2956 1808 1221 E-VENT 5/180 with a fan 230 V 480 1800 90 3926 2401 1622 E-VENT 6/60 with a fan 230 V 570 600 90 1199 733 495 E-VENT 6/100 with a fan 230 V 570 1000 90 2300 1407 950 E-VENT 6/140 with a fan 230 V 570 1400 90 3610 2208 1492 E-VENT 6/180 with a fan 230 V 570 1800 90 4779 2923 1975 E-VENT 8/60 with a fan 230 V 755 600 90 1591 973 657 E-VENT 8/100 with a fan 230 V 755 1000 90 2928 1791 1210 E-VENT 8/140 with a fan 230 V 755 1400 90 4375 2676 1808 E-VENT 10/60 with a fan 230 V 935 600 90 2036 1245 841 E-VENT 10/100 with a fan 230 V 935 1000 90 3840 2349 1587 E-VENT 10/140 with a fan 230 V 935 1400 90 5912 3616 2443 E-VENT 12/60 with a fan 230 V 1115 600 90 2397 1466 990 E-VENT 12/100 with a fan 230 V 1115 1000 90 4599 2813 1900 E-VENT 12/140 with a fan 230 V 1115 1400 90 7220 4416 2983 - Correction coefficients
Room temperature tz tp 5 8 12 16 20 22 24 95 90 0.583 0.603 0.632 0.663 0.699 0.718 0.738 85 0.599 0.620 0.651 0.685 0.723 0.743 0.765 80 0.617 0.639 0.672 0.708 0.748 0.770 0.794 75 0.635 0.659 0.694 0.733 0.776 0.806 0.825 70 0.655 0.681 0.718 0.759 0.806 0.832 0.859 90 85 0.617 0.639 0.672 0.708 0.748 0.770 0.794 80 0.635 0.659 0.694 0.733 0.776 0.806 0.825 75 0.655 0.681 0.718 0.759 0.806 0.832 0.859 70 0.676 0.703 0.743 0.788 0.839 0.866 0.896 65 0.699 0.728 0.770 0.819 0.874 0.904 0.937 85 80 0.655 0.681 0.718 0.759 0.806 0.832 0.859 75 0.676 0.703 0.743 0.788 0.839 0.866 0.896 70 0.699 0.728 0.770 0.819 0.874 0.904 0.937 65 0.723 0.754 0.800 0.852 0.912 0.945 0.981 60 0.748 0.782 0.832 0.889 0.954 0.990 1.030 80 75 0.699 0.728 0.770 0.819 0.874 0.904 0.937 70 0.723 0.754 0.800 0.852 0.912 0.945 0.981 65 0.748 0.782 0.832 0.889 0.954 0.990 1.030 60 0.776 0.812 0.866 0.928 1.000 1.040 1.083 55 0.806 0.845 0.904 0.972 1.050 1.095 1.143 75 70 0.748 0.782 0.832 0.889 0.954 0.990 1.030 65 0.776 0.812 0.866 0.928 1.000 1.040 1.083 60 0.806 0.845 0.904 0.972 1.050 1.095 1.143 55 0.839 0.881 0.945 1.019 1.107 1.156 1.211 50 0.874 0.920 0.990 1.072 1.169 1.225 1.286 70 65 0.806 0.845 0.904 0.972 1.050 1.095 1.143 60 0.839 0.881 0.945 1.019 1.107 1.156 1.211 55 0.874 0.920 0.990 1.072 1.169 1.225 1.286 50 0.912 0.963 1.040 1.131 1.240 1.303 1.373 45 0.954 1.009 1.095 1.197 1.320 1.391 1.471 65 60 0.874 0.920 0.990 1.072 1.169 1.225 1.286 55 0.912 0.963 1.040 1.131 1.240 1.303 1.373 50 0.954 1.009 1.095 1.197 1.320 1.391 1.471 60 55 0.954 1.009 1.095 1.197 1.320 1.391 1.471 50 1.000 1.061 1.156 1.271 1.410 1.493 1.585 45 1.050 1.119 1.225 1.354 1.515 1.611 1.719 40 1.107 1.183 1.303 1.450 1.636 1.749 1.879 55 50 1.050 1.119 1.225 1.354 1.515 1.611 1.719 45 1.107 1.183 1.303 1.450 1.635 1.749 1.879 40 1.169 1.255 1.391 1.561 1.780 1.914 2.071 35 1.240 1.337 1.493 1.691 1.951 2.115 2.308 50 45 1.169 1.255 1.391 1.561 1.780 1.914 2.071 40 1.240 1.337 1.493 1.691 1.951 2.115 2.308 35 1.320 1.430 1.611 1.844 2.160 2.363 2.609 30 1.410 1.538 1.749 2.029 2.420 2.679 3.001 45 40 1.320 1.43 1.611 1.844 2.160 2.363 2.609 35 1.410 1.538 1.749 2.029 2.420 2.679 3.001 30 1.515 1.663 1.914 2.257 2.752 3.094 3.535 40 35 1.515 1.663 1.914 2.257 2.752 3.094 3.535 30 1.636 1.811 2.115 2.542 3.194 3.666 4.307 Description:
tz – Flow temperature
tp – Return temperatureIn the description of the heater parameters tz appears as the first value, tp as the second, and the room temperature as the third, e.g. 55/45/20
To calculate the heating power for non-standard supply parameters, divide the heating power for parameter 75/65/20 by the value read from the correction factor table.
For example, we are looking for the heating power for the S6/60 radiator for the parameter 70/50/20. The power for 75/65/20 is 922 W. In the table of correction factors, we read the coefficient for: tz = 70, tp = 50, room temperature = 20. In the table of correction coefficients read the value of the coefficient for: tz = 70, tp = 50, room temperature = 20. For these parameters the coefficient is: 1,246.
Therefore: 922/1,246 ≈740 W- Accessories included
HEATER ACCESSORIES SUPPLIED TOGETHER WITH THE RADIATOR, INCLUDED IN THE PRICE.
A set of wall hangers or a set of feet for floor mounting (one option to be selected), dowels, screws, air vent, in the bottom-supplied heaters a thermoregulatory valve with pre-adjustment, connection gaskets and installation manual.
- Accessories & controls
Accessories and proposed control options for heaters with 230V fan
Fan module EV060/230V
for the heater with the length 60 cmFan module EV080/230V
for the heater of the length 80 cmFan module EV100/230V
for the heater of length 100 cmFan module EV120/230V
for the heater of length 120 cmFan module EV140/230V
for the heater with the length 140 cmFan module EV160/230V
for the heater of the length 160 cmFan module EV180/230V
for the heater of length 180 cmFan module EV200/230V
for the heater of length 200 cmv.1.0
SALUS RT200 electronic temperature controller
Bimetallic thermostat controlling the operation of fans. Wiring must be used between the duct fan and the thermostat (electrical cable: 4 x min. 0.5 mm).
LED lighting.v.2.0
SALUS CONTROL
The electronic thermostat FC600 enables local control of both trench heaters and wall mounted radiators.
Features:
- Touch panel and picture menu
- automatic or manual fan speed regulation
- Possibility to connect supply temperature sensor CT10X
- time schedule: 5+2, 7-day, daily
- after expansion with internet gateway UGE600 remote control is possible
- memory for settings in case of power loss
- possibility of connecting wireless OS600 window/door opening sensor
- SmartPlug SPE600 can be connected
Use wiring between the duct fan and the thermostat (minimum 0.5 mm²)
v.3.0
SIEMENS CONTROL
Electronic thermostat that controls the operation of the fans.
Basic features:
- three-stage control of fan operation (automatic gear selection as a function of temperature, possibility of manual operation),
- automatic control of the thermal actuator,
- weekly work schedule programming function,
- flush mounted,
- installation in a standard 60mm electrical box
- compatible with remote control: IRA 211.
Control system SP01 230V 60Wup to 8 fans. Flush box – dimensions: h. 53mm, w.. 109mm, L. 132mmWiring: between RDF 600T thermostat and control SP01 (SP06) electrical cable 6 x min. 0,5 mm2).
Electric cable 3 x min. between fan motor and control system. 0,5 mm2.Thermoelectric actuator – T30NC 230V M30x1,5 – (currentless closed)
- Warranty
WARRANTY CONDITIONS
25 YEARS WARRANTY!!!
REGULUS®-system radiators are covered by a 25-year warranty – the warranty covers the tightness of heaters water system. Heater lifespan is comparable to the lifespan of copper installations and may be even several dozen years!
WARRANTY CONDITIONS
REGULUS®-system spółka jawna (general partnership) with its registered office at 51 Grażyńskiego Street in Bielsko-Biała, Poland, gives a warranty for its products: REGULUS®-system water-filled radiators.
The Manufacturer declares that the REGULUS®-system radiators are made in accordance with the EN-442 European Standard.
The Manufacturer’s warranty covers the leaktightness of the radiator water system. The warranty period varies depending on the place of application, thus, it is:
25 YEARS for radiators for facilities with microclimates typical of residential premises, offices and the like.
10 YEARS for radiators for facilities with high moisture of air and an increased hygiene and health regime, like swimming pools, car washes, drying rooms, vessels, commercial premises and all kinds of industrial buildings, including the port infrastructure.
- This warranty does not affect any of the consumer’s statutory rights relating to the product type’s incompatibility with the sales agreement.
- The User’s rights under this warranty may only be exercised via the company, from which the product was purchased. They may be exercised directly at the Manufacturer’s only if the point of sale, in which the product was purchased, has been closed down.
- This warranty shall be valid from the date of purchase as specified in the purchase document. The User’s rights under this warranty may only be exercised upon production of the purchase document along with the confirmed Warranty Card.
- If an event covered by the warranty occurs in the warranty period, the complaining User can demand the radiator to be replaced with another one of the same type.
- The new product shall be given to the User at the place of defect notification within 14 days from the date of notification. On reception of the new product, the User shall return the faulty radiator, unless the event has occurred during the ongoing heating season. In such a case, the faulty radiator shall be returned after the actual replacement.
- The Manufacturer shall cover the costs of the replacement of the faulty radiator with a new, fault-free one after receiving the relevant bill. The costs of this service shall be agreed on between the Manufacturer and the User in advance.
- Warranties for the control fittings shall be provided by their respective manufacturers.
- The Manufacturer’s warranty does not cover the functions and durability built in the thermostatic valves in bottom-fed radiators. These are covered by their manufacturer’s warranties.
ITEMS NOT COVERED BY THIS WARRANTY
- Any defects resulting from misuse of the product. Permissible system operating parameters: Water temperature – 110 °C, operating pressure – 1.5 MPa.
- Leakages resulting from incorrect installation of the radiator, the valve air vent or their components, and particularly from defrosting or using wrong sealing materials. Side-fed radiators are fitted with a rotatable half union for front sealing with gaskets.
- Defects and inconveniences resulting from incorrect installation or incorrect plumbing adjustment of the radiator and system water pollution.
- Mechanically damaged products (in particular with traces of impact, scratches, dents, twists – e.g. air vent or pipe sockets) shall not be subject to replacement.
- The warranty shall be void when the User or anyone else modifies or repairs any product of the REGULUS®-system company without authorization.
- The warranty shall be void when the mechanical filter mounted on the power supply of the central heating system, to which the REGULUS®-system radiators are connected, is removed. This particularly refers to a system with steel components.
- The REGULUS®-system company reserves the right to modify its products without prior notice.
ITEMS NOT AFFECTING THE WARRANTY
- Any kind of divisor mounted on the external surface of REGULUS®-system radiators, provided this does not damage the radiator water system.
- REGULUS®-system radiators mounted within open central heating systems.
- Radiators mounted within systems supplied directly by the municipal heat distribution network, not by way of a heat exchanger.
- Periodic emptying of the central heating system, provided the other system components allow for such an operation and the operation will not make the components corrode.
The User receiving the product together with the Warranty Card accepts all the above warranty terms.
- Download